... object CT, its series connection to the secondary winding of test object CT. Specification Rated Current: 5A; 1A Power Factor and Rated Capacity: COSФ=0.8:2.5/ 3.75/ 5/ 6.25/ 7.5/ 10/ 12.5/ 15/ 20/ 30/ 40/ ...
... object CT, its series connection to the secondary winding of test object CT. Specification Rated Current: 5A; 1A Power Factor and Rated Capacity: COSФ=0.8:2.5/ 3.75/ 5/ 6.25/ 7.5/ 10/ 12.5/ 15/ 20/ 30/ 40/ ... more
Brand Name:GFUVE
Model Number:GF106Y-1
Place of Origin:BEIJING CHINA
-
..., 1A Working Current Range 1-120% or up to 200% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Working Frequency 50/60HZ Basic Error Active (±3+0.003*...
..., 1A Working Current Range 1-120% or up to 200% Rated Impedance (Ω) COSφ= 0.8 0.1;0.15;0.2;0.3;0.4;;0.6;1.0;1.2; 1.6; 2.4; 3.2 COSφ= 1.0 0.1;0.15;0.2;0.3;0.4 Working Frequency 50/60HZ Basic Error Active (±3+0.003*... more
Brand Name:HNMC
Model Number:FL2
Place of Origin:China
LED CT PT Testing , 5A Current Transformer Burden Test
-
...Current Transformer , 100A , 50mA The split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easier and portable current measurement. An internal precision burden resistor...
...Current Transformer , 100A , 50mA The split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easier and portable current measurement. An internal precision burden resistor... more
Brand Name:Shinhom
Model Number:SCTK681C Series
Place of Origin:China
100A 50mA Mechanical Split Core Current Transformer
-
...Current Transformer Testing Equipment Introduction: CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer. CPT-III Power Current Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test. CPT-III Power Current Transformer
...Current Transformer Testing Equipment Introduction: CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer. CPT-III Power Current Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test. CPT-III Power Current Transformer more
Brand Name:Delta
Model Number:CPT-III
Place of Origin:China
CPT-III 220V to 500kv Power Current Transformer Testing Equipment
-
...Current Transformer and PT Potential Current Testing Equipment is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. CT Current Transformer and PT Potential Current...
...Current Transformer and PT Potential Current Testing Equipment is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. CT Current Transformer and PT Potential Current... more
Brand Name:AI
Model Number:CPT-I
Place of Origin:China
CT Current Transformer and PT Potential Current Testing Equipment
-
... open type current transformer This current transformer is beautiful in appearance, easy to install and connect.It is mainly used in power operation and maintenance and power transformation projects. It usually outputs small current signals such as 0-100mA...
... open type current transformer This current transformer is beautiful in appearance, easy to install and connect.It is mainly used in power operation and maintenance and power transformation projects. It usually outputs small current signals such as 0-100mA... more
Brand Name:Acrel
Model Number:AKH-0.66K-φ24
Place of Origin:China
Low Voltage 1 Burden Split Core Current Transformer IP30 Strong Load Capacity
-
...Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard according with:IEC60044-1:2003 2. Specification rated transformation ratio(A) Accuary classes combination rated output(VA) (ALF) (FS) short-time thermal current Ith(kA/S) rated dynamic current...
...Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard according with:IEC60044-1:2003 2. Specification rated transformation ratio(A) Accuary classes combination rated output(VA) (ALF) (FS) short-time thermal current Ith(kA/S) rated dynamic current... more
Brand Name:XG
Model Number:LZZW-10
Place of Origin:XIAN,CHINA
LZZW-10 10kv 11kv 12kv Outdoor CT Current Transformer
-
... or 60Hz and highest voltage for equipment 17.5kV. Technical Data 1. Installation site Outdoor 2. Rated Frequency 50/60Hz 3. Burden power factor cosΦ=0.8(lagging) 4.
-
... Voltage Test: 4KVeff,50Hz,1Min ·Weight: 200-250gr Rated Current(A) Primary/Secondary 30/5A 40/5A 50/5A 60/5A 75/5A 80/5A 100/5A Accuracy Class 3 1.0 1.0 1.0 1.0 Rated Burden(VA) 1 1.5 2.5 2.5 2.5 Outline Drawing Of
-
...transformer adjustable resistor variable load potentiometer disc product name: BC1 -type rotor -type variable resistor/BC1 disc adjustable resistor/BC1 disk variable resistor/BC1 variable resistor/BC1 porcelain disk resistor/BC1 porcelain disk resistor Circular disk resistor BC1 25W 50W 100W 200W 300W 1K adjustable potentiometer wire wound ceramic disk resistor...
...transformer adjustable resistor variable load potentiometer disc product name: BC1 -type rotor -type variable resistor/BC1 disc adjustable resistor/BC1 disk variable resistor/BC1 variable resistor/BC1 porcelain disk resistor/BC1 porcelain disk resistor Circular disk resistor BC1 25W 50W 100W 200W 300W 1K adjustable potentiometer wire wound ceramic disk resistor... more
Brand Name:BONENS
Model Number:BC1
Place of Origin:China
BC1 Sliding Transformer Adjustable Resistor Variable Load Potentiometer Disc
-
... for Current and Voltage Transformer Test Testing for current transformer equipment: 1 Excitation curve and parameters test 2 Turns ratio test 3 Ratio and phase error test 4 Polarity mark check 5 Winding resistance measurement 6 Secondary loop burden ...
-
...Current Transformer wide current range 200A ratio 1:1 KE6323-200 Isolation current transformer KE6323-200 Isolation current transformer (ICT) is used for the test of I-P close link meter. When test the three phase meters, the voltage and current circuit cannot be separated, it needs to isolate the voltage and current...
...Current Transformer wide current range 200A ratio 1:1 KE6323-200 Isolation current transformer KE6323-200 Isolation current transformer (ICT) is used for the test of I-P close link meter. When test the three phase meters, the voltage and current circuit cannot be separated, it needs to isolate the voltage and current... more
Brand Name:KRE
Model Number:KE6323-200
Place of Origin:China
Wide Current Range Isolation Current Transformer Three Phase 200A RS485 Port
-
...Current Transformer Testing Equipment Introduction: CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer. CPT-III Power Current Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test. CPT-III Power Current Transformer
...Current Transformer Testing Equipment Introduction: CPT-III Power Current Transformer Testing Equipment is used to measure all kinds of current transformer and voltage transformer. CPT-III Power Current Transformer Testing Equipment can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one test. CPT-III Power Current Transformer more
Brand Name:Delta
Model Number:CPT-III
Place of Origin:China
CPT-III 220V to 500kv Power Current Transformer Testing Equipment
-
...Transformer CT PT Analyzer Parameters MODEL ZXHQ-B Test standards IEC60044-1, IEC60044-6, C57.13 Output 0~180Vrms 12Arms 36A(peak) knee voltage measurement 60kV Voltage measurement accuracy ±0.2% Current measurement / CT Ratio Range 1~40000 accuracy max 0.05% PT ratio Range 1~40000 accuracy max 0.05% Phase error ±2min resolution 0.5min DC resistance Range 0~300Ω accuracy 0.2%±2mΩ Secondary Burden...
...Transformer CT PT Analyzer Parameters MODEL ZXHQ-B Test standards IEC60044-1, IEC60044-6, C57.13 Output 0~180Vrms 12Arms 36A(peak) knee voltage measurement 60kV Voltage measurement accuracy ±0.2% Current measurement / CT Ratio Range 1~40000 accuracy max 0.05% PT ratio Range 1~40000 accuracy max 0.05% Phase error ±2min resolution 0.5min DC resistance Range 0~300Ω accuracy 0.2%±2mΩ Secondary Burden... more
Brand Name:GDZX
Model Number:ZXHQ-B+
Place of Origin:CHINA
Current Transformer Voltage Transformer CT PT Ratio Phase Accuracy Winding Resistance Tester
-
... or bus-bars 4) Wide range of sizes to accommodate all the existing installations. 5) Primary current from 5A to 5000A Specification Model Nominal current ratio Burden(VA)/Accuracy 0.5 1.0 DP-58 250/5A / 2.5 300/5A / 2.5 400/5A 2.5 2.5 500/5A 2.5 5 600/5A
-
Clamp on current transformer(specifications) Rated Primary current 1-200A Turn ratio 1:1000 1:2000 1:2500 Output 0.333V 1.5V Accuracy 0.1, 0.2 ,1.0 Class Second burden(Ohms) ≦5, ≦50 ,≧100k Dielectric Resistance 1000MOhms @ 500 Vdc Case Material ...
Clamp on current transformer(specifications) Rated Primary current 1-200A Turn ratio 1:1000 1:2000 1:2500 Output 0.333V 1.5V Accuracy 0.1, 0.2 ,1.0 Class Second burden(Ohms) ≦5, ≦50 ,≧100k Dielectric Resistance 1000MOhms @ 500 Vdc Case Material ... more
Brand Name:grewin
Place of Origin:Tianjin, China
Certification:CE ROHS
clamp on current transformer
-
...depends entirely on the load current of the circuit being tested, but not on the secondary current; The current coil impedance of the current Transformer secondary coil and the relay are very small, so under normal circumstances, the current Transformer is
...depends entirely on the load current of the circuit being tested, but not on the secondary current; The current coil impedance of the current Transformer secondary coil and the relay are very small, so under normal circumstances, the current Transformer is more
Brand Name:QIUPU
Model Number:LZZBJ9-35
Place of Origin:WENZHOU
Casting Resin Indoor High Voltage Current Transformer Single Phase / 3 Phase
-
...current transformer EE5.0 3+3 The voltage ratio of this product is 1:100 and 1:75, single-phase power supply, 1W rated power, open, high frequency current transformer, E-type iron core, SMD surface sticker, efficiency (η) is 96%, applicable scope is communication and vehicle power supply. Ferrite mini patch high frequency current transformer EE5.0 3+3 Product Name: EE5 .0 surface mounted Current transformer...
...current transformer EE5.0 3+3 The voltage ratio of this product is 1:100 and 1:75, single-phase power supply, 1W rated power, open, high frequency current transformer, E-type iron core, SMD surface sticker, efficiency (η) is 96%, applicable scope is communication and vehicle power supply. Ferrite mini patch high frequency current transformer EE5.0 3+3 Product Name: EE5 .0 surface mounted Current transformer... more
Brand Name:ED8
Model Number:EE5.0 3+3 1:75 1:100
Place of Origin:China,shenzhen city.
Ferrite Mini Patch High Frequency Current Transformer EE5.0 3+3
-
... EMI suppression 350uH minmum OCL with 8mA bias current 1. Current Rating 1.5 amps 2. Voltage Rating 125vac 3. Insulation Resistance 500 MΩmin 4. Contact Resistance 30 MΩmax 5. Withstanding Voltage ...
-
...Current Transformer Tester 1.1 Application Tests for current transformer Tests for voltage transformer Applications for CTPT analyzer Excitation curve and parameters test Turns ratio test CT nameplate check Turns ratio test Phase angle error test CT parameters check in work burden Ratio and phase error test Polarity test CT transient parameters analysis Polarity mark check Secondary burden...
...Current Transformer Tester 1.1 Application Tests for current transformer Tests for voltage transformer Applications for CTPT analyzer Excitation curve and parameters test Turns ratio test CT nameplate check Turns ratio test Phase angle error test CT parameters check in work burden Ratio and phase error test Polarity test CT transient parameters analysis Polarity mark check Secondary burden... more
Brand Name:Gold
Model Number:GDVA-405
Place of Origin:Chongqing of China
GDVA-405 CT/PT Potential & Current Transformer Tester