Home >

Digital Patient Monitor Machine / Surgical Monitoring Machine In Hospital

Categories Patient Monitor Machine
Brand Name: Feilong
Model Number: FL-PM8000
Place of Origin: Henan, China
MOQ: Negotiable
Price: Negotiable
Payment Terms: L/C, T/T
Supply Ability: 2,500 sets per month
Delivery Time: 30-40 working days after received your deposit
Packaging Details: Standard export wooden case or pallet package
Type: Monitoring Machine In Hospital
Power: Digital
Dimension: 314 mm(L) x 145 mm(W) x 264 mm(H)
Weight: <3.9 kg(excluding battery and accessories)
Display: LCD display
Other Name: Monitoring Machine In Hospital
  • Product Details
  • Company Profile

Digital Patient Monitor Machine / Surgical Monitoring Machine In Hospital

Digital Patient Monitor Machine / Surgical Monitoring Machine In Hospital


Functions

Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP

ECG

Heart rate(HR)

ECG waveform

Arrhythmia and ST-segment analysis

RESP

Respiration rate(RR)

Respiration waveform

SpO2

Oxygen saturation(SpO2)

Plethysmogram(PLETH) waveform

Pulse rate(PR)

Bar graph

NIBP

Systolic pressure(SYS), Diastolic pressure(DIA), Mean

pressure(MEAN)

TEMP

TI, T2, TD

IBP(optional)

CH1: SYS, DIA, MAP

CH2: SYS, DIA, MAP

IBP waveform

CO2(optional)

EtCO2

InsCO2: Inspired Minimum CO2

AWRR: Air Way Respiration

It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Accessories

Adult fingertip SpO2 probe (5-pin)

Adult NIBP cuff

NIBP extension tube

ECG lead cable

ECG electrode

Temperature probe

Power cord

User Manual

Physical characteristic

Dimension: 314 mm(L) x 145 mm(W) x 264 mm(H)

Weight: <3.9 kg(excluding battery and accessories)

Features


l Maximum 8-channel waveform synchronous display.

l Display 7-lead ECG waveform on one screen, cascade ECG waveform display.

l Adopt digital Sp02 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.

l Heart rate variability (HRV) analysis function.

l NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.

l Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.

l Drug concentration calculation and titration table functions.

l One-touch printing of trend graph.

l Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.

l AC/DC, built-in rechargeable lithium battery achieve uninterrupted

monitoring.

l Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).


Performance

ECG

Lead mode: 3-lead: 1, II, II 5-lead: I, II, II, aVR, aVL, aVF, V

Waveform: 3-lead, 1-channel 5-lead, 2-channel

Gain: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV

Scan speed: 12.5 mm/s, 25 mm/s, 50 mm/s

HR: Measurement and alarm range: 15-350 bpm

Resolution: 1 bpm

Accuracy: +1% or ±1 bpm, whichever is greater

Alarm accuracy: ± 2 bpm

ST-segment monitoring:

Measurement and alarm range: -2.0 mV ~+2.0 mV

Accuracy: -0.8 mV~ +0.8 mV: ±0.04 mV or ± 10%, whichever is greater

Other range: unspecified

Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Pacemaker: yes


RESP

Method: R-F(RA-LL) Impedance

Respiration rate:

Measurement and alarm range: 0~150 rpm

Resolution: 1 rpm

Measurement accuracy:±2 rpm

Apnea alarm: 10 - 40 s

Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s


NIBP

Method: Oscillometry

Mode: Manual/AUTO/STAT

Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes

Measurement period in STAT mode: 5 minutes

Measurement and alarm range: 10 - 270 mmHg

Resolution: 1 mmHg

Cuff pressure accuracy: + 3 mmHg

Measurement accuracy:

Maximal mean deviation: ±5 mmHg

Maximal standard deviation: 8 mmHg


NIBP

Over-pressure protection:

Adult mode: 297 mmHg ± 3 mmHg

Pediatric mode: 240 mmHg ± 3 mmHg

Neonatal mode: 147 mmHg ± 3 mmHg

SpO2

Measurement and alarm range: 0~100 %

Resolution: 1%

Accuracy:70~100 %: ±2 %; 0 ~ 69 %: unspecified


PR

Measurement and alarm range:25~250 bpm

Measurement accuracy: ±2 bpm or ± 2 %, whichever is greater


TEMP

Channel: dual-channel

Measurement and alarm range: 0 ~ 50℃

Resolution: 0.1 ℃


Accuracy: ± 0.1 ℃


EtCO2

Method: Sidestream or Mainstream

Measuring Range: 0~150 mmHg

Resolution: 0 ~ 69 mmHg: 0.1 mmHg, 70 - 150 mmHg: 0.25 mmHg

Accuracy: 0 - 40 mm Hg: ±2 mm Hg,41 - 70 mm Hg: ± 5 %, 71 - 100 mm Hg: ± 8 %, 101 - 150 mm Hg: ± 10 %

AWRR Range: 2~150 rpm

AWRR Accuracy: ±1rpm

Apnea Alarm: Yes

Quality Digital Patient Monitor Machine / Surgical Monitoring Machine In Hospital wholesale
Send your message to this supplier
 
*From:
*To: Zhengzhou Feilong Medical Equipment Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    More from this Supplier