Medium Voltage power Cable | Cu-Conductor, XLPE insulated, copper tape screened electrical cable

Categories Medium Voltage Power Cables
Brand Name: Chengtiantai Cable
Model Number: YJV
Certification: CCC
Place of Origin: China Mainland
MOQ: 500 m
Price: On Request
Payment Terms: L/C, T/T
Delivery Time: 15 working days
Packaging Details: Steel wooden Drum, On request
  • Product Details
  • Company Profile

Medium Voltage power Cable | Cu-Conductor, XLPE insulated, copper tape screened electrical cable

Medium Voltage Power Cable single core 6/10 kV, 12/20 kV, 18/30 kV to IEC 60502


XLPE Insulated, Copper conductor, singe core, screened, PVC sheathed

APPLICATIONS


The singe core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 6/10 KV to 18/30KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.


CABLE CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– Annealed copper tapes with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. SHEATH

– Outer sheath of PVC compound

TECHNICAL DATA

>>Temperature range
– during installation up to -5°C

>>Operating temperature
– max. +90°C

>>Short circuit temperature
+250°C (short circuit duration max. 5 s)

>>Minimum bending radius
– 20 x cable Ø

>>Breaking strength: min. 200%
>>Tensile strength: min. 12,5 N/mm2

>>Nominal voltage
– U0/U 6/10 kV, 12/20 kV, 18/30 kV

>>Operating voltage, 50 Hz
– for 6/10 kV = max. 12 kV
– for 12/20 kV = max. 24 kV
– for 18/30 kV = max. 36 kV

>>Test voltage(V/5 min)
– for 6/10 kV = 21 kV
– for 12/20 kV = 42 kV
– for 18/30 kV = 63 kV


6/10 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed


No.cores x
cross-sec.
Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²kVkVmmmmmmkg / kmAAΩ/km
1 x 35 rm126/ 103.41.620.66872051900.52
1 x 50 rm126/ 103.41.7228552452250.39
1 x 70 rm126/ 103.41.723.610863052750.27
1 x 95 rm126/ 103.41.825.513513703300.19
1 x 120 rm126/ 103.41.826.916224303750.15
1 x 150 rm126/ 103.41.928.619324904250.12
1 x 185 rm126/ 103.41.930.322995604800.1
1 x 240 rm126/ 103.42.032.728646655550.08
1 x 300 rm126/ 103.42.135.334597656300.06
1 x 400 rm126/ 103.42.238.645548907250.05
1 x 500 rm126/ 103.42.342.2557410308250.04
1 x 630 rm126/ 103.42.445.9686711909400.03

12/20 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed


No.cores x
cross-sec.
Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²kVkVmmmmmmkg / kmAAΩ/km
1 x 35 rm2412/ 205.51.824.98602051900.52
1 x 50 rm2412/ 205.51.826.411382452250.39
1 x 70 rm2412/ 205.51.928.112813052750.27
1 x 95 rm2412/ 205.51.929.915703703300.19
1 x 120 rm2412/ 205.5231.318394303750.15
1 x 150 rm2412/ 205.5233.121744904250.12
1 x 185 rm2412/ 205.52.134.725405604800.1
1 x 240 rm2412/ 205.52.237.131206655550.08
1 x 300 rm2412/ 205.52.239.537467656300.06
1 x 400 rm2412/ 205.52.344.148638907250.05
1 x 500 rm2412/ 205.52.447.6590510308250.04
1 x 630 rm2412/ 205.52.551.3722011909400.03

18/30 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed


No.cores x
cross-sec.
Operation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²kVkVmmmmmmkg / kmAAΩ/km
1 x 50 rm3618/ 308232.613632452250.39
1 x 70 rm3618/ 308234.316143052750.27
1 x 95 rm3618/ 3082.136.119193703300.19
1 x 120 rm3618/ 3082.137.522034303750.15
1 x 150 rm3618/ 3082.239.325564904250.12
1 x 185 rm3618/ 3082.240.929345604800.1
1 x 240 rm3618/ 3082.343.335406655550.08
1 x 300 rm3618/ 3082.445.741917656300.06
1 x 400 rm3618/ 3082.549.152468907250.05
1 x 500 rm3618/ 3082.654.6656110308250.04
1 x 630 rm3618/ 3082.758.4790611909400.03


*Dimensions and specifications may be changed without prior notice.


MEDIUM VOLTAGE CABLE TESTING


Routine tests:Sample tests:Type tests:
These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath
These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test
These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

Shenzhen chengtiantai cable operates certified management systems compliant with:
CertificatInformation
ISO 9001:2008
Quality management systems

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 9th January 2022
ISO 14001:2004
Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 9th January 2022

OHSAS 18001:2007
Assessment specification for occupational health & safety management systemsenvironmental management systems
Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 9th January 2022

Some great shot on our manufacturing plant


Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106

WARRANTY


For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Quality Medium Voltage power Cable | Cu-Conductor, XLPE insulated, copper tape screened electrical cable wholesale
Send your message to this supplier
 
*From:
*To: Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly