Power accuracy level: | 0.1 |
Voltage amplitude accuracy: | 0.02% RD+10mV |
Current amplitude accuracy: | 0.05% RD+20uA |
power error: | <0.1% |
gear setting voltage: | 500V, 1000V |
DC Power Calibration Of 3 Phase Energy Meter , Safe Voltage Current Calibrator
1. Main features
The XL-9060 DC energy meter verification device is the latest DC
power meter verification series device designed and developed by
Shenzhen Xinglong Technology Co., Ltd. In view of the need for DC
power meter verification on the market, the national standard of DC
energy meter is adopted, and the latest technology is adopted. The
main components are imported industrial grade devices, which can
support DC current output of 0~60ADC, DC of 0~1000V. Voltage
output, 0~5V DC voltage analog shunt output, accuracy grade better
than 0.05%. It also supports voltage and current output ripple
superposition function, which can be used for virtual load
verification of DC energy meter, ripple interference test, or as a
separate voltage standard source, current standard source, and
power standard source.
The device adopts 800×600 liquid crystal display, the interface is
clear and simple, the operation is convenient, and the visual
effect is good. Waveform quantization uses 32-bit dual modulation
output technology to ensure high output accuracy. The output has
overcurrent and overheat protection, which is safe and reliable.
2. Main functions
Main function Description
DC voltage output Support 0~1000V DC voltage output, accuracy:
<0.02%
DC current output Support 0~60A DC current output, accuracy:
<0.05%
Small signal output Support 0~5V DC voltage output, accuracy:
<0.05%
Error calculation Support automatic error calculation of upper
software
Start test support
Latent test support
Ripple test support
Generate report support
3. Technical indicators
No. Name Indicator range
1 Power accuracy level 0.1
2 Voltage amplitude accuracy 0.02% RD+10mV
3 Current amplitude accuracy 0.05% RD+20uA
4 small signal amplitude accuracy Uo ≤ 4 mV: 0.05 % RD +10 uV;
4 mV ≤ Uo ≤ 5 V: 0.05 % RD
5 power error <0.1%
6 output phase number 1 channel voltage, 1 channel current, 1
channel small signal
7 gear setting voltage: 500V, 1000V
Current: 0.02A, 0.2A, 1A, 5A, 10A, 20A, 60A
Small signal: 2.5mV, 20mV, 100mV, 1V, 5V
8 Output stability (/min) Voltage: full scale better than 0.01%,
typically 0.005%
Current: full scale better than 0.01%, typically 0.005%
Small signal: 75mV file: full scale is better than 0. 02%
5V file: full scale is better than 0. 02%
9 Output power Current: <60VA, port voltage: <2V
Voltage: <60VA, output current: <60mA
Small signal: Uo<0.1V: 1mA,
Uo≥0.1V: 10mA
10 Long-term stability Voltage and current: ±100PPM/year
11 Ripple superposition Frequency: 20~500Hz
Ripple voltage accuracy: 20-500Hz: <1%
Ripple current accuracy: 20-200Hz: <1%
200-500Hz: <5%
![]() |