Home > Testing Equipment >

Multi Phase Voltage Calibration Source , Standard Electrical Test Meter Calibration

Categories Energy Meter Calibration Equipment
Brand Name: XL
Model Number: XL-833
Certification: CE
Place of Origin: China
MOQ: negotiate
Price: negotiate
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 800 pcs per month
Delivery Time: 3~4 weeks
Packaging Details: external packing:carton or non wooden box;cushion packing:EPE foam
Name: Energy Meter Calibration Equipment
Output range: 0A, 0.01A ~ 100A
Adjustment fineness: 0.01% RG
Accuracy: better than ±0.05% RG
Stability: better than 0.02% RG /1min
Harmonic number: 21 times
Harmonic content rate: 100% below 5A
Gear setting: 0.2A~1A, 1A~10A, 10A~50A, 50A~100A
  • Product Details
  • Company Profile

Multi Phase Voltage Calibration Source , Standard Electrical Test Meter Calibration

Multi Phase Voltage Calibration Source , Standard Electrical Test Meter Calibration


1. Function Description


1) High-precision programmable voltage and current output, amplitude, phase and frequency are arbitrarily adjustable
2) Support state sequence output mode, state switching delay is less than 100uS
3) Support the trigger signal, start the output when the trigger pulse arrives, and the trigger delay is less than or equal to 100us
4) Support multiple devices to synchronize output synchronously under the synchronization signal, and use GPS second pulse signal to achieve long-distance synchronization
5) Support recording playback function
6) The multi-phase currents are isolated from each other and can be output in parallel. The total output current is the vector sum of the multi-phase outputs. The total current can be obtained by setting the phase to the same phase.
7) Note: Multi-phase voltages are not isolated and cannot be used in series or in parallel. In severe cases, the equipment will be burnt.


2. Application field


Distribution network terminal test, transformer test, electric energy meter test, etc. where large output power and output current are required


3. Main features of the product


1) It is possible to output a pure sinusoidal power signal with a distortion of 0.05% (typical).
2) The frequency output can be adjusted from 40Hz to 100Hz, the resolution is 0.001Hz, and the accuracy is 0.002Hz.
3) Each phase frequency is individually adjustable, so it can be phase-separated.
4) The phase 0~360 degrees can be adjusted arbitrarily, which can easily simulate various power supply situations and even reverse power transmission.
5) Strong load capacity, full load capacity, inductive, resistive load or composite type load, and the load regulation rate is better than 0.05% RG.
6) Excellent temperature stability, the core device is a military grade product with a temperature coefficient as small as 1PPM, which can guarantee the output precision in the outdoor temperature environment.
7) It is powerful and flexible with 32-bit MCU+DSP processor.
8) The waveform of the power frequency is up to 50,000 points per week, and the internal signal output is smoothed without filters. It ensures the accurate output of the waveform, making the output of higher harmonics possible, and the system has excellent harmonic distortion. Degree indicator.
9) It has RJ45 network port and RS232 port for convenient connection with PC or secondary development.
10) Improve the protection function.
11) Hardware PID, response time is less than 100us.
12) Typical load regulation is less than one in ten thousand.
13) The main control module + expansion module combination structure can be easily combined into a 1~4 phase test system.
14) Multiphase currents can be connected in parallel to obtain a large current output.
15) Provide multi-platform protocol library interface to facilitate secondary development of users. The specific development platform is welcome to call us.


4. Technical indicators


4.1. AC current output


Name:Energy Meter Calibration EquipmentOutput Range:0A, 0.01A ~ 100A
Adjustment Fineness:0.01% RGAccuracy:Better Than ±0.05% RG
Stability:Better Than 0.02% RG /1minHarmonic Number:21 Times
Harmonic Content Rate:100% Below 5AGear Setting:0.2A~1A, 1A~10A, 10A~50A, 50A~100A

Temperature drift 10PPM/°C
Long-term stability 100PPM/year


4. 2. AC voltage output


Output range 0~450V
Adjustment fineness 0.01% RG
Accuracy is better than 0.05% RG
Stability better than 0.02% RG /1min
Harmonic number 21 times
Harmonic content rate is not less than 100% below 100V, 100%~100% of 100V~150V, 30%~100% of 150V~220V, and not less than 20% above 220V
Harmonic accuracy is better than 0.2%
Distortion better than 0.1% (typically 0.05%, non-capacitive load)
Output power Maximum single phase 100VA (can be customized to 300VA)
Full load adjustment rate less than 0.05% RG
Full load adjustment time is less than 1ms
Gear setting 0V~100V, 100V~260V, 260V~450V
Temperature drift 10PPM/°C
Long-term stability less than 100PPM/year

Quality Multi Phase Voltage Calibration Source , Standard Electrical Test Meter Calibration wholesale
Send your message to this supplier
 
*From:
*To: XL Science And Technology Co. Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    More from this Supplier
    Contact Us Quickly